Measurement of the elastic modulus of porcine septal cartilage specimens following Nd:YAG laser treatment

机译:Nd:YAG激光处理后猪中隔软骨标本的弹性模量的测量

获取原文
获取原文并翻译 | 示例

摘要

Abstract: In this study we measured the mechanical properties of porcine septal cartilage before and after Nd:YAG laser ($lambda equals 1.32 micrometer, 21.22 W/cm$+2$/) radiation using parameters and conditions encountered during laser-mediated cartilage reshaping. During laser irradiation, specimens were linearly translated at constant velocity while surface temperature was monitored radiometrically with a thermopile sensor. Irradiation was terminated when surface temperature reached approximately 70 degrees Celsius. Force versus displacement curves were generated in cantilevered specimens using a calibrated thin beam load cell and a single motorized micropositioner (velocity equals .762 mm/sec). Measurements were determined immediately before and after laser irradiation, and then following hydration in saline solution (40 minutes, 25 degrees Celsius). Elastic modulus was calculated using a model assuming linear viscoelastic behavior. Specimens boiled in saline (one hour, 100 degrees Celsius and then re-hydrated) were also evaluated as these tissues are completely denatured. The calculated moduli before and after irradiation were 4.86 plus or minus .145 and 1.166 plus or minus .055 Mpa respectively. Following re-hydration in saline, the modulus returned to near-baseline values (5.119 plus or minus .163 Mpa). In contrast, elasticity remained lower in specimens boiled and re-hydrated (3.25 plus or minus .130 Mpa). These findings suggest that cartilage matrix properties have not been significantly altered following laser irradiation and that the mechanical properties of the tissue are maintained. !32
机译:摘要:在这项研究中,我们使用激光介导的软骨重塑过程中遇到的参数和条件,测量了Nd:YAG激光(λ等于1.32微米,21.22 W / cm $ + 2 $ /)辐射前后的猪中隔软骨的力学性能。在激光照射过程中,以恒定速度线性移动样品,同时用热电堆传感器以辐射方式监测表面温度。当表面温度达到约70摄氏度时终止辐照。使用经过校准的薄膜称重传感器和单个电动微型定位器(速度等于.762 mm / sec),在悬臂样品中生成力与位移曲线。在激光辐照之前和之后,然后在盐溶液中水合(40分钟,25摄氏度)之后立即确定测量值。使用假设线性粘弹性行为的模型计算弹性模量。由于这些组织已完全变性,因此还评估了在盐水中煮沸的标本(一小时,100摄氏度,然后重新水合)。辐照前后的模量分别为4.86正负.145和1.166正负.055 Mpa。在盐水中重新水化后,模量恢复到接近基线值(5.119正负0.163 Mpa)。相反,煮沸并重新水化的样品的弹性仍然较低(3.25正负.130 Mpa)。这些发现表明,在激光照射后,软骨基质的性质没有显着改变,并且组织的机械性质得以保持。 !32

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号