首页> 外文会议>International Workshop on Service Life Design for Underground Structures; 200610; Shanghai,(CN) >STUDY ON STRAY CURRENT INTENSITY AND ITS EFFECT ON SUBWAY STRUCTURES DURABILITY
【24h】

STUDY ON STRAY CURRENT INTENSITY AND ITS EFFECT ON SUBWAY STRUCTURES DURABILITY

机译:杂散电流强度及其对地铁结构耐久性的影响研究

获取原文
获取原文并翻译 | 示例

摘要

During the motion of subway train operated by direct current, there is part of the direct current, named leaking current or stray current, leaking into underground soil and structures. The stray current could cause steel bars in reinforced concrete elements of underground structures to corrode. The reinforce concrete elements corroded by stary current decreases their intensity and durability. Based on the analyses of the formation of stray current and the mechanism of reinforcement corrosion in Metro lines, this paper compares major influencing factors of Metro stray current intensity and their influences extent. The durability of underground or Metro structures influenced by Metro stray current is also analyzed in this paper. The results of this paper can be references to the subway structure durablity design.
机译:在以直流电为动力的地铁列车运行过程中,有一部分直流电(称为漏电流或杂散电流)泄漏到地下土壤和建筑物中。杂散电流可能导致地下结构的钢筋混凝土构件中的钢筋腐蚀。受到星流腐蚀的钢筋混凝土构件会降低其强度和耐久性。在分析地铁线路杂散电流的形成和增强腐蚀机理的基础上,比较了地铁杂散电流强度的主要影响因素及其影响程度。本文还分析了受地铁杂散电流影响的地下或地铁结构的耐久性。本文的研究结果可为地铁结构耐久性设计提供参考。