Applicability of steel fiber reinforced high-strength shotcrete to a squeezing tunnel

机译:钢纤维增强高强喷射混凝土在挤压隧道中的适用性

获取原文
获取原文并翻译 | 示例

摘要

In order to clarify the reasonable conditions under which a steel fiber reinforced high-strength sprayed concrete lining (SFRS) can be applied to a squeezing tunnel with time dependency; a numerical analysis of non-linearity is conducted. The advance velocity of the tunnel face progress, the time dependency of the strength of SFRS, the elasto-plastic behavior of the steel supports, and the visco-elastic characteristics of the ground are all taken into account in the analysis. A comparison between analytical and field measurement results shows that the results obtained through this analysis have sufficient accuracy for practical applications. Consideration is given to the use of SFRS to a squeezing tunnel.
机译:为了阐明合理的条件,在一定条件下可以将钢纤维增强高强喷射混凝土衬砌(SFRS)应用于挤压隧道;进行了非线性数值分析。分析中考虑了隧道工作面的前进速度,SFRS强度的时间依赖性,钢支架的弹塑性行为以及地基的粘弹特性。分析结果和现场测量结果之间的比较表明,通过该分析获得的结果对于实际应用具有足够的准确性。考虑在挤压隧道中使用SFRS。