首页> 外文会议>International Symposium on High Voltage Engineering; 20050825-29; Beijing(CN) >Measurement of Power Frequency Electric Magnetic Field in a 500kV Substation
【24h】

Measurement of Power Frequency Electric Magnetic Field in a 500kV Substation

机译:500kV变电站工频电场和磁场的测量

获取原文
获取原文并翻译 | 示例

摘要

Measurement of power frequency electric & magnetic field (PEMF) in a 500kV air insulated substation has been conducted. The distribution of power frequency electric & magnetic field along certain routes and magnitudes beside equipments are reported. The results of measurement are compared with the guidelines in standards. The results show that the values of power frequency electric and magnetic field accord with the guidelines of ICNIRP, but the values of electric field in 500kV equipment area and magnetic field around reactor exceed the guidelines of national standard, which should be paid enough attention in electric power industry.
机译:已对500kV空气绝缘变电站的工频电场和磁场(PEMF)进行了测量。报告了设备旁沿某些路径和幅度的工频电场和磁场的分布。将测量结果与标准指南进行比较。结果表明,工频电场和磁场的值符合ICNIRP的规定,但500kV设备区的电场和电抗器周围的磁场的值均超过国家标准的规定,在电气上应引起足够重视电力行业。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号