首页> 外文会议>International Symposium on Heating, Ventilating and Air Conditioning vol.2; 20031009-11; Beijing(CN) >EXPERIMENTAL STUDY ON THE PERFORMANCE OF EVAPORATOR AND CONDENSER HEAT EXCHANGERS IN A TRAIN-USED AIR CONDITIONING GROUP
【24h】

EXPERIMENTAL STUDY ON THE PERFORMANCE OF EVAPORATOR AND CONDENSER HEAT EXCHANGERS IN A TRAIN-USED AIR CONDITIONING GROUP

机译:火车用空调机组中蒸发器和冷凝器换热器性能的实验研究

获取原文
获取原文并翻译 | 示例

摘要

This paper presents the measuring procedure, the experimental results and the evaluation for the air conditioning group used in a high-speed train compartment. The target of these tests is to determine the evaporator and condenser performance at the given design conditions. The finned coil condenser and evaporator are installed in air ducts and to control the flow going through the heat exchangers as recommended for the air-heated and air-cooled heat exchangers specific test (ASHRAE Standard 33-1978R, 1999, European Standard EN 1216, 1999). The evaporator and the condenser of the air conditioning group are tested separately in order to have the better control for reaching the design conditions. A simulation model is also developed here to standardize the test results to the required conditions.
机译:本文介绍了高速列车车厢中使用的空调组的测量程序,实验结果和评估。这些测试的目标是确定在给定设计条件下的蒸发器和冷凝器性能。翅片盘管冷凝器和蒸发器安装在风管中,并按照风冷和风冷热交换器的特定测试的建议(ASHRAE标准33-1978R,1999,欧洲标准EN 1216, 1999)。空调组的蒸发器和冷凝器分别进行测试,以便更好地控制达到设计条件。这里还开发了一个仿真模型,以将测试结果标准化到所需条件。