In the paper the tests result of a two-phase loop TPL with the capillary pump (CP) in conditions of absence of gravitation are indicated. To test were subjected 3 TPL onboard space vehicles (SV) Horizon per 1980-1981. The tests have shown large sensitivity to a priming doze by a coolant, than in conditions of a gravitation. Depending on magnitude of a coolant priming doze and conditions of start three stable operational modes TPL are detected which have thermophysical parameters. The necessity of the guaranteed impregnation of a capillary structure CP and capillary equalizer before start TPL is confirmed. For start three in parallel joint CP the minimum thermal potency has made approximately 40W. TPL with a capillary structure from a titanum alloy, material of pipelines from a stainless steel on freon-11 in general has studied without a noticeable modification thermophysical of parameters 1 year 10 months. The further gains on improving serviceability CP should be directed on increase of reliability of the guaranteed start and maintainings of a constant of temperature cooled of the payment for want of modification of a transmitted potency.
机译:在本文中,指出了在没有重力的情况下使用毛细管泵(CP)进行的两相环路TPL的测试结果。根据1980-1981年的测试,对3辆TPL机载航天器(Horizo​​n)进行了测试。测试显示,与重力作用相比,冷却剂对打底打ze的灵敏度更高。根据冷却剂灌注打ze的大小和启动条件,检测到三个具有热物理参数的稳定运行模式TPL。确定了在启动TPL之前必须确保浸渍毛细管结构CP和毛细管均衡器的必要性。对于并联的第三个关节CP,最小热效率约为40W。具有钛合金毛细管结构的TPL,氟利昂11上的不锈钢管道材料通常经过1年10个月的研究,未对参数的热物理性质进行明显修改。改善可维修性CP的进一步收益应针对保证启动的可靠性的提高以及由于不希望改变传输效能而使支付的冷却温度保持恒定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号