The moisture content has great effect on capacitance transducer for measuring concentration of two-phase flow of solid/gas. The paper describes an method of correction the error caused by moisture content in capacitance transducer by designing feedback parameters specially. The experimental results showed when variation of moisture content between 0.5%-2% . The measurement error of the concentration of two-phase flow of solid-gas could be restrain below 5% .
机译:水分含量对测量固体/气体两相流浓度的电容传感器有很大的影响。本文介绍了一种通过专门设计反馈参数来校正电容传感器中水分含量引起的误差的方法。实验结果表明,当水分含量在0.5%-2%之间变化时。固相气两相流浓度的测量误差可以控制在5%以下。