首页> 外文会议>International Conference on Enhanced Building Operations; 20061106-08; Shenzhen(CN) >The Optimization of Control Parameters for VAV HVAC System Commissioning
【24h】

The Optimization of Control Parameters for VAV HVAC System Commissioning

机译:变风量空调系统调试控制参数的优化

获取原文
获取原文并翻译 | 示例

摘要

One of the technical subjects in commissioning for HVAC system is to enhance control performance and time efficiency, while the tuning of the optimal parameters to control HVAC system takes much time and labor in particular. Therefore, we propose a kind of commissioning technique as follows. We identified the dynamic characteristics of components of an actual VAV HVAC system such as rooms, VAV dampers, two way valves and chilled water coils, and verified the behaviors of the models and choose the optimal control parameters on a personal computer. Then adopting them for the actual system, we verified the control performance. Through the procedure, we showed the possibility of off-site and off-line control parameter tuning to reduce the cost and time at on-site and in on-line using the measured data in a real HVAC system.
机译:暖通空调系统调试的技术主题之一是提高控制性能和时间效率,而调整最佳参数以控制暖通空调系统特别耗时且费力。因此,我们提出以下一种调试技术。我们确定了实际的VAV HVAC系统组件的动态特性,例如房间,VAV风门,二通阀和冷水盘管,并验证了模型的行为并在个人计算机上选择了最佳控制参数。然后将它们用于实际系统,我们验证了控制性能。通过该过程,我们展示了使用真实HVAC系统中的测量数据进行现场和离线控制参数调整以减少现场和在线成本和时间的可能性。