首页> 外文会议>International Confederation for Thermal Analysis and Calorimetry Congress 2016 >Product Analysis for Snack Confectionery with Fragmentless Ionization Mass Spectrometry
【24h】

Product Analysis for Snack Confectionery with Fragmentless Ionization Mass Spectrometry

机译:无碎片电离质谱分析零食的产品

获取原文
获取原文并翻译 | 示例

摘要

The fragmentless ionization that is a kind of soft-ionization generates no fragment ions. It is different from e.g., conventional electron ionization technique for mass spectrometry. Thus one peak in a mass spectrum indicates one ingredient evolved from a specimen, and the m/z value corresponds to molecular weight. Because separation of chemical species is carried out in the mass spectrum, there is an advantage of no requirement for separation such as GC. ?The fragmentless ionization mass spectrometry can offer rapid screening because of the unnecessary of the pretreatment separation techniques. In this study, we present product analysis for snack confectionery with two types of fragmentless ionization mass spectrometry, Photo Ionization (PI) and Ion Attachment ionization (IA). Samples were 7 kinds of commercial snack confectionery on the Japan's market, so-called as chips. The 2 kinds of samples are non-fry artifacts. We used TG-DTA/PI-MS named ThermoMass Photo by Rigaku Co. and DIP/IA-MS named IA-Lab by Canon ANELVA Co. The TG-DTA/PI-MS was used mainly for the analysis of the pyrolyzed gas species of wheat and potato, and the DIP/IA-MS was used mainly for the analysis of fry oil. DIP/IA-MS detected peaks due to triglyceride as quasi-molecular ions without any pretreatment, i.e., derivatization of fatty acids. Therefore the estimation of fatty acid composition was possible. When detected peak intensity on triglyceride species of 7 kinds of snack confectionery was plotted against lipid amount described on the wrapping bags, good linearity was obtained, so that quantitative evaluation is possible with his method. Further the change of mass spectra due to wheat amount and detection of erucic acid that is unsaturated fatty acid with the fear which causes a heart obstacle by surplus ingestion, will be also presented.
机译:无碎片电离是一种软电离,不会产生碎片离子。它不同于例如用于质谱法的常规电子电离技术。因此,质谱图中的一个峰表示从样品中析出的一种成分,并且m / z值对应于分子量。由于化学物种的分离是在质谱图中进行的,因此具有无需分离(例如GC)的优势。 ?由于不需要分离预处理技术,因此无碎片电离质谱可以提供快速筛选。在这项研究中,我们用两种类型的无碎片电离质谱法,即光子电离(PI)和离子附着电离(IA),对零食糖果进行产品分析。样品是日本市场上7种所谓的薯片商业零食糖果。这两种样本是非油炸的伪影。我们使用了由Rigaku Co.命名为ThermoMass Photo的TG-DTA / PI-MS和由Canon ANELVA Co.命名为IA-Lab的DIP / IA-MS。该TG-DTA / PI-MS主要用于分析热解气体种类DIP / IA-MS主要用于分析油炸油。 DIP / IA-MS在未进行任何预处理即脂肪酸衍生化的情况下,检测到了由甘油三酸酯作为准分子离子引起的峰。因此,可以估计脂肪酸组成。当将检测到的7种小吃糖果的甘油三酸酯种类的峰强度与包装袋上描述的脂质量作图时,可获得良好的线性,因此可以用他的方法进行定量评估。此外,还将提出由于小麦的量引起的质谱变化和作为不饱和脂肪酸的芥酸的检测,担心会因过量摄入而引起心脏障碍。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号