In order to improve the energy efficiency of traditional room air conditioners, this paper presented the heat pipe combined evaporative cooling room air conditioner. This study built the mathematical model and carried out programming to make simulation analysis on the annual dynamical operating performance of the heat pipe combined evaporative cooling room air conditioner under different area parameters of heat exchangers, and then took into account the economic factors, to obtain that the optimal areas of evaporator and condenser were respectively 14.89 m~2 and 23.07 m~2. In addition, based on the optimal areas, it was concluded that the COP of the combined room air conditioner increased by 33.27%, and energy consumption reduced by 32.83%, comparing with traditional air conditioner, which didn’t include evaporative cooling technology and separate type heat pipe technology.
机译:为了提高传统房间空调的能效,提出了一种热管组合式蒸发冷却房间空调。本研究建立了数学模型并进行了编程,对换热器不同面积参数下的热管式蒸发冷却室空调器的年动态运行性能进行了仿真分析,然后考虑了经济因素,得出蒸发器和冷凝器的最佳面积分别为14.89 m〜2和23.07 m〜2。此外,根据最佳区域,得出的结论是,与传统的不包含蒸发冷却技术和独立式空调的空调相比,组合式空调的COP提高了33.27%,能耗降低了32.83%。型热管技术。