首页> 外文会议>International Conference on Sustainable Energy, Electronics, and Computing Systems >Determination of optimal location for sensors implementing non-invasive methods for evaluating the capacity of Window Air Conditioner
【24h】

Determination of optimal location for sensors implementing non-invasive methods for evaluating the capacity of Window Air Conditioner

机译:确定传感器的最佳位置,该传感器采用非侵入性方法来评估车窗空调的能力

获取原文

摘要

The placement of sensors holds critical importance when it comes to estimation of capacity of a window air conditioner (AC). The paper provides experimental results indicating a variation in the capacity of an AC, when calculated for sensors placed at different locations. The experimental test set-up is based on ISO 5151: Air Enthalpy Method for determining the cooling capacity of an AC. The set-up also implements psychrometric chart as provided by ASHRAE to calculate air properties. The performance of sensors has been found identical at a particular location and the data been used to estimate the capacity in BTU per hour. The optimal location thus found may be used to design a Non Invasive Instrument for the determination of performance of a window AC.
机译:在估算车窗空调(AC)的容量时,传感器的位置至关重要。该论文提供的实验结果表明,当针对放置在不同位置的传感器进行计算时,交流电的容量会发生变化。实验测试设置基于ISO 5151:用于确定AC冷却能力的空气焓法。该设置还实施了ASHRAE提供的湿度计以计算空气特性。已经发现传感器的性能在特定位置相同,并且该数据用于估计每小时BTU的容量。因此找到的最佳位置可用于设计非侵入式仪器,以确定窗户AC的性能。