Window systems such as air flow window, Push-pull window and high performance general window make it possible to maintain space thermal comfort without individual air conditioning equipment for perimeter zone. The Purpose of this paper is to establish an evaluation method of window side radiant environment for determination of Proper window system. A simulation method of space radiant environment was shown and “operative temperature increase on window side” was defined as an index of window side radiant environment. Comfort range of this index was Proposed by using PMV. From a simulation analysis for a glass-covered office building, basic characteristics of three types of window system became clear.
机译:诸如通风窗,推拉窗和高性能通用窗之类的窗户系统使维持周边空间的热舒适性成为可能,而无需使用单独的空调设备。本文的目的是建立一种确定适当窗户系统的窗户侧辐射环境的评估方法。给出了空间辐射环境的仿真方法,并将“窗侧工作温度升高”定义为窗侧辐射环境的指标。通过使用PMV提出了该指数的舒适范围。通过对玻璃覆盖的办公楼的仿真分析,可以清楚地了解三种类型的窗户系统的基本特征。