The paper describes the results of the study of an optimum interval for switching the stages of the capacitor unit (CU), which can improve the efficiency of automatic control of reactive power, reduce the wear and tear of the switching equipment and capacitors and prolong their service life period. The urgency of the research is determined by the lack of well-founded recommendations on the selection of the optimum switching interval for the CU stages. The recommendations on the selection of the optimum switching interval for CU stages are developed on the basis of the numerical simulation method using real reactive power curves of consumers and the Lab+ software program modelling the reactive power regulator. The optimum interval for switching capacitor banks, indicated in the settings of the automatic reactive power controller, is determined in relation to the reactive load conditions. For medium and abruptly variable reactive loads, it is very important to accurately monitor the load changes and control the reactive power generation at the maximum frequency, i.e., to use a minimum switching interval for the CU stages, which is to be no less than 120 seconds. For weakly variable loads, setting a minimum control interval does not lead to a significant reduction in the reactive power flow, and even increases the power flow in some cases. Therefore, prolonged switching intervals of 8, 15, 30 minutes are the most efficient and cost-effective for loads that do not significantly vary over time. The results obtained can help to improve the efficiency of automatic control of CU reactive power.
机译:本文描述了用于切换电容器单元(CU)的最佳间隔的研究结果,该间隔可以提高无功功率自动控制的效率,减少开关设备和电容器的损耗,并延长电容器的使用寿命。使用寿命。缺乏针对CU级选择最佳开关间隔的可靠建议决定了研究的紧迫性。根据使用用户的实际无功功率曲线的数值模拟方法以及对无功调节器进行建模的Lab +软件程序,在针对CU级选择最佳开关间隔的建议上提出了建议。自动无功功率控制器设置中指示的切换电容器组的最佳间隔是根据无功负载条件确定的。对于中等和突变的无功负载,准确监控负载变化并控制最大频率下的无功功率非常重要,即对CU级使用最小切换间隔,该间隔应不小于120秒。对于弱变负载,设置最小控制间隔不会导致无功功率流的显着减少,在某些情况下甚至会增加功率流。因此,对于随时间变化不大的负载,延长切换间隔8、15、30分钟是最有效和最具成本效益的。获得的结果有助于提高CU无功功率自动控制的效率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号