To keep normal running of UHVDC in addition to the active control reactive power control were needed to maintain a normal commutation voltage of converter valve. Reactive power control need coordinate with priority of each level control when considering filtering and voltage stability. Traditional reactive power and voltage control does not generally consider the priority issues of reactive power control. In order to analysis the mechanism of reactive power and voltage control of UHVDC. Take the ±800kV Jinsu UHVDC as background, based on the study on the filter configuration, detailed analysis of the relationship between the priority of the five control levels for reactive and voltage control as well as the its control principles were make. Research results indicates that the reactive power control strategies of UHVDC have five levels as abs min filter control, Umax/Umin control, Qmax control, min filter control and U/Q control under priority from low to high.
机译:为了保持UHVDC的正常运行,除了有功控制之外,还需要无功功率控制来维持换流阀的正常换向电压。考虑滤波和电压稳定性时,无功功率控制需要与每个级别控制的优先级协调。传统的无功功率和电压控制通常不考虑无功功率控制的优先级问题。为了分析特高压直流无功和电压控制的机理。以±800kV晋苏特高压直流输电为背景,在对滤波器配置进行研究的基础上,详细分析了无功和电压控制五个控制等级的优先级之间的关系及其控制原理。研究结果表明,特高压直流无功功率控制策略从低到高依次具有abs最小滤波控制,Umax / Umin控制,Qmax控制,最小滤波控制和U / Q控制五个等级。