To detect a neurotransmitter in the nervous system simultaneously, we developed a pattering technique using a cross-linkable polymer to immobilize apyrase on a charge coupled device (CCD)-type image sensor. An apyrase-immobilized membrane was patterned by the proposed technique and characteristics of the fabricated ATP-image sensor are reported in our previous report. The bio-image sensor determines ATP concentrations by measuring the formed H+ ions from an enzymatic reaction in real-time. However, on the experiment, it was difficult to distinguish between the produced H+ions and the other H+ ions that are diffused from nearby membranes or other origins. In this study, the diffusion characteristics of H+ions for bio-image sensor was measured and evaluated. The results used to determine a measurement time that can minimize the undesirable impact of the diffused ions.
机译:为了同时检测神经系统中的神经递质,我们开发了一种图案化技术,使用可交联聚合物将腺苷三磷酸酶固定在电荷耦合器件(CCD)型图像传感器上。通过提出的技术对固定有腺苷三磷酸双磷酸酶的膜进行构图,并且在我们以前的报告中报道了制造的ATP图像传感器的特性。生物图像传感器通过实时测量酶促反应形成的H +离子来确定ATP浓度。但是,在实验中,很难区分产生的H +离子和从附近膜或其他来源扩散的其他H +离子。在这项研究中,对生物图像传感器中H +离子的扩散特性进行了测量和评估。用于确定测量时间的结果可以最大程度地减少扩散离子的不良影响。