This paper presents a novel 24-slot/14-pole modular symmetric six-phase permanent magnet (PM) machine which manage to reduce magnetomotive force (MMF) harmonics and achieve high magnetic isolation features. Polyphase fault-tolerant drives constructed with full-bridge inverters are usually expensive and bulky. In this paper, 6-phase/8-leg and 6-phase/9-leg voltage source inverters (VSIs) are proposed and investigated in order to reach a compromise between system cost and fault-tolerant ability. Additionally, two remediation methods are adopted and compared for one-phase and two-phase open circuit fault.
机译:本文介绍了一种新颖的24槽/ 14极模块化对称六相永磁(PM)电机,该电机可减少磁通势(MMF)谐波并实现高磁隔离特性。由全桥逆变器构成的多相容错驱动器通常很昂贵且笨重。本文提出并研究了六相/ 8脚和6相/ 9脚电压源逆变器(VSI),以在系统成本和容错能力之间达成折衷。此外,针对一相和两相开路故障,采用了两种补救方法并进行了比较。