This paper proposes a fault tolerant control method of an open-switch fault for a single IGBT in two parallel-connected three-phase AC/DC PWM converter systems. Recently, parallel converter has been widely used in the high power application. However, if the open-switch fault of the IGBT occur in the parallel converter, faulty condition causes the dc-link voltage fluctuation, the distorted grid current and the circulating current of the zero sequence. These problems could be mitigated by using the conventional fault tolerant control methods for the single converter, but the distorted grid current cannot satisfy the grid code. Therefore, this paper proposes the new fault tolerant control method by using the combination control of the two converters to compensate the distorted current of the fault side converter. Both dc-link voltage fluctuation and the THD of the grid current can be improved by applying the proposed fault tolerant control method. The performance and the effectiveness of the proposed fault tolerant control method are verified through the simulation.
机译:本文提出了一种在两个并联的三相AC / DC PWM转换器系统中单个IGBT的开路开关故障的容错控制方法。近来,并行转换器已被广泛用于高功率应用中。但是,如果并联转换器中发生IGBT的开路故障,则故障状况会导致直流母线电压波动,电网电流失真和零序循环电流。这些问题可以通过对单个转换器使用常规的容错控制方法来缓解,但是失真的电网电流不能满足电网规范。因此,本文提出了一种新的容错控制方法,即利用两个转换器的组合控制来补偿故障侧转换器的畸变电流。通过应用所提出的容错控制方法,可以改善直流母线电压波动和电网电流的总谐波失真。通过仿真验证了所提容错控制方法的性能和有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号