首页> 外文会议>HTD-vol.376-1; ASME(American Society of Mechanical Engineers) International Mechanical Engineering Congress and Exposition; 20051105-11; Orlando,FL(US) >THERMAL ASSESSMENT OF COOLING SYSTEM INCORPORATING HEAT SINK AND EMBEDDED HEAT PIPES FOR TESTING HIGH POWER MICROELECTRONICS
【24h】

THERMAL ASSESSMENT OF COOLING SYSTEM INCORPORATING HEAT SINK AND EMBEDDED HEAT PIPES FOR TESTING HIGH POWER MICROELECTRONICS

机译:包含热沉和嵌入式热管的冷却系统的热评估,以测试高功率微电子

获取原文
获取原文并翻译 | 示例

摘要

A numerical study was conducted to model the transient thermal behavior of a complex testing system including multiple fans, a mixing enclosure, copper inserts and a leaded package dissipating large amounts of power over short time durations. The system is optimized by choosing appropriate heat sink/fan structure for the efficient operation of the device under constant powering. The intent of the study is to provide a better understanding and prediction of a transient powering scenario at high powering levels, while evaluating the impact of alternative cooling fan/heat pipe designs on the thermal performance of the testing system. One design is chosen due to its effective thermal performance and assembly simplicity, with the package embedded in heat sink base with multiple (5) heat pipes. The peak temperature reached by the modified design with 4 cooling fans is ~ 95℃, with the corresponding Rja thermal resistance ~0.58℃/W. For the transient study (with embedded heat pipes and 4 fans), after one cycle, both peak temperature (at 45 s) and the end temperature (at 49 s) decrease as compared to the previous no heat pipe/single fan case (the end temperature reduces by ~16%). The temperature drop between peak and end for each cycle is ~80.2℃, while the average power per transient cycle is ~31.27W. With this power, the design with 5 perpendicular heat pipes, 4 fans and insert reaches a steady state peak temperature of ~98℃. Applying the superposition principle to the steady state value and 40.1℃ fluctuation, the maximum transient temperature after a large number of cycles will not exceed ~138.1℃, satisfying the thermal budget under the current operating conditions. The benefit of the study is related to the possibility to extract the maximum and minimum temperatures for a real test involving a large number of heating-cooling cycles, yet maintaining the initial and peak temperatures within a certain range for the optimal operation of the device. The flow and heat transfer fields are investigated; using a combination of numerical and analytical methods, the thermal performance of the device undergoing large number of periodic thermal cycles is predicted. The comparison between measurement and simulation shows good agreement.
机译:进行了数值研究,以对复杂的测试系统的瞬态热行为进行建模,该系统包括多个风扇,一个混合外壳,铜质插入件和一个带引线的封装,可在短时间内耗散大量功率。通过选择合适的散热器/风扇结构来优化系统,以在恒定功率下使设备高效运行。该研究的目的是为了更好地理解和预测高功率水平下的瞬态功率情况,同时评估备选冷却风扇/热管设计对测试系统热性能的影响。由于其有效的热性能和组装简单性,选择了一种设计,该封装嵌入具有多(5)个热管的散热器底座中。改进设计的4个冷却风扇达到的峰值温度为〜95℃,相应的Rja热阻为〜0.58℃/ W。对于瞬态研究(具有嵌入式热管和4个风扇),在一个周期后,与以前的无热管/单个风扇的情况相比,峰值温度(45 s)和最终温度(49 s)均降低。最终温度降低了〜16%)。每个周期的峰值与终点之间的温度降为〜80.2℃,而每个瞬态周期的平均功率为〜31.27W。借助此功率,带有5个垂直热管,4个风扇和插入件的设计可以达到约98℃的稳态峰值温度。将叠加原理应用于稳态值和40.1℃波动,经过多次循环后的最高瞬态温度将不超过〜138.1℃,满足当前工作条件下的热预算。这项研究的好处与为涉及大量加热-冷却循环的实际测试中提取最高和最低温度的可能性有关,但仍可将初始温度和峰值温度保持在一定范围内,以使设备达到最佳运行状态。研究了流场和传热场。通过使用数值和分析方法的组合,可以预测设备经历大量周期性热循环的热性能。测量与仿真的比较显示出良好的一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号