首页> 外文会议>High-power lasers and applications VIII >Interstitial optical parameter quantification of turbid medium based on CW radiance measurements
【24h】

Interstitial optical parameter quantification of turbid medium based on CW radiance measurements

机译:基于连续波辐射测量的混浊介质的间隙光学参数定量

获取原文
获取原文并翻译 | 示例

摘要

CW radiance measurements examine the light intensity at a single source-detector location from different detection directions to recover absorption coefficient and reduced scattering coefficient of the turbid medium which is important in treatment planning of minimally invasive laser therapies. In this paper, P9 approximation for radiance is used as the forward model for fitting by considering the balance between computational time and the correctness of the forward model at low albedo and small source detector separation (SDS). By fitting P9 approximation for radiance to the angular radiance Monte Carlo (MC) simulations used as the angular radiance measurements, optical parameters are recovered over a wide range of reduced albedo between 0.69 and 0.99 at small SDS 2mm. The recovery errors of absorption coefficient and reduced scattering coefficient are less than 11.96% and 2.63%, respectively. The effects of the maximum angle used for fitting on optical parameter recovery have been further studied. The results show that the recovery errors of absorption coefficient and reduced scattering coefficient are less than 12% and 3% respectively when the maximum angle is greater than 70 degree.
机译:连续波辐射度测量从不同的检测方向检查单个光源检测器位置处的光强度,以恢复混浊介质的吸收系数和降低的散射系数,这在微创激光治疗的治疗计划中很重要。在考虑低反照率和小源探测器分离(SDS)时,计算时间和正向模型正确性之间的平衡,将辐射的P9近似值用作拟合的正向模型。通过将辐射的P9近似值拟合为用作角辐射度测量的角辐射度蒙特卡罗(MC)模拟,可以在小SDS 2mm的0.69至0.99之间的宽反照率范围内恢复光学参数。吸收系数和降低的散射系数的恢复误差分别小于11.96%和2.63%。进一步研究了用于拟合的最大角度对光学参数恢复的影响。结果表明,当最大夹角大于70度时,吸收系数和减小的散射系数的恢复误差分别小于12%和3%。

著录项

  • 来源
    《High-power lasers and applications VIII》|2016年|1002436.1-1002436.6|共6页
  • 会议地点 Beijing(CN)
  • 作者单位

    College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China, 300072;

    College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China, 300072,Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, China, 300072;

    College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China, 300072,Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, China, 300072;

    College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China, 300072,Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, China, 300072;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Radiance; Pn approximation; optical parameter recovery;