The reduction of leakage from potable water supply is an essential element in the strategy to achieve sustainable use of the most precious natural resource. Both electromagnetic (EM) induction and acoustic surveys were performed at the Esholt Hall controlled leak test site in West Yorkshire. A Geonics EM-38 was used to build a 13.5 x 35.5m grid, with readings every 0.25 m and survey lines 0.5 m apart. The EM survey showed that the water saturation from the leak caused an increase in bulk ground conductivity, this ~20mS/m increase was observable at the surface. The acoustic trials were performed using Radcom SoundSens~(TM) acoustic loggers. Three different survey styles were used, all of which were at the surface and did not require access to the pipe network. The increase in amplitude adjacent to the leak position was observed during all of the acoustic surveys. This initial success should be built on before these techniques can be applied within industry.
机译:减少饮用水的泄漏是实现可持续利用最珍贵的自然资源的战略中的基本要素。电磁(EM)感应和声学测量均在西约克郡的Esholt Hall控制的泄漏测试现场进行。用Geonics EM-38建造了一个13.5 x 35.5m的网格,每0.25 m读数一次,而测量线相距0.5 m。 EM调查表明,泄漏引起的水饱和导致地面导电率增加,在地面上可观察到约20mS / m的增加。使用Radcom SoundSensTM声学记录仪进行声学测试。使用了三种不同的勘测样式,所有这些勘测样式都在地面上,不需要访问管网。在所有声学调查中都观察到邻近泄漏位置的幅度增加。在将这些技术应用到工业中之前,应该建立起最初的成功。