Abstract: DSRI will provide a set of four imaging proportional counters for the Danish-Soviet x-ray telescopes XSPECT/SODART. The sensor principle is based on the novel micro-strip proportional counter (MSPC), where the strip electrodes are deposited by photolithography onto a rigid substrate. The MSPC offers many advantages: a uniform gas gain, an excellent energy resolution, the possibility to match the strip pitch to the desired positron resolution, a fast charge collection, and low operating voltages. However, a stable behavior of the MSPC requires a careful choice of both substrate and strip electrode material. The low energy detectors are equipped with polyimide windows of 0.5 $mu@m thickness, providing a high quantum efficiency even at 200 eV with an energy resolution comparable to that of solid state detectors. The MSPC is capable of operating at high counting rates (10$+5$/ ph s$+$MIN1$/) and the electronics are designed to match this capability. !10
机译:摘要:DSRI将为丹麦苏维埃X射线望远镜XSPECT / SODART提供一组四个成像比例计数器。传感器原理基于新型微带比例计数器(MSPC),其中带状电极通过光刻技术沉积到刚性基板上。 MSPC具有许多优点:均匀的气体增益,出色的能量分辨率,使带间距与所需的正电子分辨率相匹配的可能性,快速的电荷收集以及低的工作电压。但是,MSPC的稳定行为需要仔细选择衬底和带状电极材料。低能探测器配备了厚度为0.5μm的聚酰亚胺窗口,即使在200 eV时也能提供高量子效率,其能量分辨率可与固态探测器媲美。 MSPC能够以高计数率(10 $ + 5 $ / ph s $ + $ MIN1 $ /)运行,并且电子设备也设计为与该功能匹配。 !10

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号