Pronounced corrosion damage occurs in supercritical water oxidation system, especially at sub-critical conditions, and few materials are immune to attack. In this paper, the corrosion phenomena of GH132 alloy tube was described, and the effect of temperature at the pressure of 24.0 MPa was discussed too. GH132 alloy tube is employed as fabricative material of pre-heater tube, which is used to heat the corrosive medium to the temperature about 300℃~350℃, and deionized water containing 0.2% H_2O_2, which is used to simulate severe oxidative environment flowing through the tube. Stress corrosion cracking (SCC) and general corrosion appear after tested for four hundred hours at 24.0 MPa. The observation of the GH132 alloy tube section by metallograph and SEM indicated the grain growth, and the SCC occurred easily due to the decrease of strength caused by the grain growth.
机译:在超临界水氧化系统中会发生明显的腐蚀破坏,特别是在亚临界条件下,并且很少有材料能够抵抗腐蚀。本文描述了GH132合金管的腐蚀现象,并讨论了温度在24.0 MPa压力下的影响。 GH132合金管作为预热管的制造材料,用于将腐蚀性介质加热到约300℃〜350℃的温度,并用含0.2%H_2O_2的去离子水模拟流过的严重氧化环境。管。在24.0 MPa下测试400小时后,出现应力腐蚀开裂(SCC)和一般腐蚀。 GH132合金管截面的金相和SEM观察表明晶粒长大,并且由于晶粒长大导致强度降低,容易发生SCC。