Use of anesthesia and the cold environment of an operating room inhibits thermoregulation in a patient body causing perioperative hypothermia. In the worst case, this situation may cause death. Maintaining normothermia is thus a key requirement during the perioperative period. In today's state-of-the-art, normothermia is maintained through a number of manual techniques, such as monitoring and controlling the temperature of the warming blankets, fluid warmers, and air conditioning system in the operating room. Since each patient illustrates different response to stimuli, a one-size-fits-all approach to maintaining normothermia is not the right approach. This paper presents ongoing work an autonomous, closed-loop control solution to maintain patient normothermia during perioperative periods.
机译:麻醉和手术室的寒冷环境会抑制患者体内的体温调节,从而导致围手术期体温过低。在最坏的情况下,这种情况可能会导致死亡。因此,维持正常体温是围手术期的关键要求。在当今的最新技术中,常温通过多种手动技术来维持,例如监视和控制手术室中的加热毯,液体加热器和空调系统的温度。由于每个患者对刺激的反应各不相同,因此一种维持正常体温的“一刀切”方法不是正确的方法。本文介绍了正在进行的工作,以在围手术期维持患者正常体温的自主闭环控制解决方案。