首页> 外文会议>Conference on Optical Metrology in Production Engineering; 20040427-20040430; Strasbourg; FR >Displacement measurements of technical surfaces with a synchronously pumped external cavity diode laser
【24h】

Displacement measurements of technical surfaces with a synchronously pumped external cavity diode laser

机译:同步泵浦外腔二极管激光器测量工业表面的位移

获取原文
获取原文并翻译 | 示例

摘要

A novel principle for absolute position measurements of rough surfaces is presented. A measurement object with a rough surface acts as an external reflector for an antireflection coated laser diode. Determining the longitudinal mode spacing yields the distance from the laser diode to the measurement object. Synchronous pumping of the laser diode results in locking of the modes of the built-up Fabry-Perot resonator. Due to resonance enhancement the mode locked external cavity laser sensor allows highly resolved displacement measurements of rough surfaces. The influence of the object as well as the active gain medium on the accuracy of the measurements is investigated by experiments and simulations.
机译:提出了一种用于粗糙表面绝对位置测量的新颖原理。具有粗糙表面的测量对象充当防反射涂层激光二极管的外部反射器。确定纵向模式间距会得出从激光二极管到测量对象的距离。激光二极管的同步泵浦会锁定已建立的Fabry-Perot谐振器的模式。由于共振的增强,锁模外腔激光传感器可以对粗糙表面进行高度分辨的位移测量。通过实验和仿真研究了对象以及有源增益介质对测量精度的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号