Toward Quantification of Breast Tomosynthesis Imaging

机译:走向乳房断层合成成像的量化

获取原文
获取原文并翻译 | 示例

摘要

Due to the high prevalence of breast cancer among women, much is being done to detect breast cancer earlier and more accurately. In current clinical practice, the most widely-used mode of breast imaging is mammography. Its main advantages are high sensitivity and low patient dose, although it is still merely a two-dimensional projection of a three-dimensional object. In digital breast tomosynthesis, a three-dimensional image of the breast can be reconstructed, but x-ray projection images of the breast are taken over a limited angular span. However, the breast tomosynthesis device itself is more similar to a digital mammography system and thus is a feasible replacement for mammography. Because of the angular undersampling in breast tomosynthesis, the reconstructed images are not considered quantitative, so a worthwhile question to answer would be whether the voxel values (VVs) in breast tomosynthesis images can be made to indicate tissue type as Hounsfield units do in CT. through some image processing scheme. To investigate this, simple phantoms were imaged consisting of layers of uniform, tissue-equivalent plastic for the background sandwiching a layer of interest containing multiple, small cuboids of tissue-equivalent plastic. After analyzing the reconstructed tomosynthesis images, it was found that the VV in each lesion increases linearly with tissue glandularity. However, for the two different x-ray tube energies and for the two different beam exposure levels tested, the trend-lines all have different slopes and y-intercepts. Thus, breast tomosynthesis has a definite potential to be quantitative, and it would be worthwhile to study other possible dependent parameters (phantom thickness, overall density, etc.) as well as alternative reconstruction algorithms.
机译:由于女性中乳腺癌的患病率很高,因此人们已经进行了很多工作,以便更早,更准确地检测出乳腺癌。在当前的临床实践中,乳房成像的最广泛使用的模式是乳房X线照相术。它的主要优点是高灵敏度和低患者剂量,尽管它仍然仅仅是三维物体的二维投影。在数字乳房断层合成中,可以重建乳房的三维图像,但是在有限的角度跨度上拍摄乳房的X射线投影图像。然而,乳房断层合成设备本身更类似于数字乳腺X线摄影系统,因此是乳腺X线摄影的可行替代。由于乳房断层合成中的角度欠采样,因此重建图像不被认为是定量的,因此一个值得回答的问题是乳房断层合成图像中的体素值(VVs)是否可以像Hounsfield单位在CT中那样指示组织类型。通过一些图像处理方案。为了对此进行研究,对简单的体模进行了成像,该体模由均匀的组织等效塑料层构成,其背景夹着包含多个组织等效塑料小立方体的目标层。对重建的断层合成图像进行分析后,发现每个病变的VV随组织腺体线性增加。但是,对于两种不同的X射线管能量以及两种不同的受测射线曝光水平,趋势线的斜率和y截距都不同。因此,乳房断层合成具有一定的定量潜力,因此有必要研究其他可能的相关参数(幻影厚度,总体密度等)以及替代重建算法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号