PURPOSE: The open-source Perk Tutor training platform has been shown to improve trainee performance in interventions that require ultrasound guidance. Our goal was to determine if needle coordination of medical trainees can be improved by training with Perk Tutor compared to training with ultrasound only. METHODS: Twenty participants with no previous experience were randomized into two groups; the Perk Tutor group and the Control group. The Perk Tutor group had access to the 3D visualization while the Control group used ultrasound only during their training. Performance was analyzed, measured and compared by Perk Tutor with regards to four needle coordination metrics. None of the groups had access to 3D visualization during performance testing. RESULTS: The needle tracking measurements showed, for the Perk Tutor group, lower average distance between the needle tip and ultrasound (1.2 [0.9 - 2.8] mm vs 2.7 [2.3 - 4.0] mm, respectively; P = 0.023) and lower maximum distance between the needle tip and ultrasound (2.2 [1.9 - 3.2] mm vs 4.6 [3.9 - 6.2] mm, respectively; P = 0.013). There was no significant difference in average needle to ultrasound plane angle and maximum needle to ultrasound plane distance. All participants were successful in the procedure. CONCLUSION: The Perk Tutor group had significantly reduced distance from the needle tip to the ultrasound plane. Training with Perk Tutor can improve trainees' needle and ultrasound coordination.
机译:目的:开源Perk Tutor培训平台已被证明可以改善需要超声引导的干预措施中学员的表现。我们的目标是确定与仅使用超声培训相比,通过Perk Tutor进行培训是否可以改善医学培训人员的针头协调性。方法:将二十名没有先前经验的参与者随机分为两组。 Perk Tutor组和Control组。 Perk Tutor组可以访问3D可视化,而对照组仅在培训期间使用超声。 Perk Tutor针对四个针头协调指标对性能进行了分析,测量和比较。在性能测试期间,没有一个组可以访问3D可视化。结果:对于Perk Tutor组,针头跟踪测量显示,针尖与超声之间的平均距离较低(分别为1.2 [0.9-2.8] mm和2.7 [2.3-4.0] mm; P = 0.023)并且最大距离较低针尖和超声之间的距离(分别为2.2 [1.9-3.2] mm和4.6 [3.9-6.2] mm; P = 0.013)。平均针与超声平面角度以及最大针与超声平面距离之间没有显着差异。所有参与者均成功完成了手术。结论:Perk Tutor组的针尖到超声平面的距离明显减小。借助Perk Tutor进行培训可以提高受训者的针头和超声波协调能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号