Empirical correlations to predict (1) drain mass flow rate, (2) temperature depression of intake air and (3) power increase to a given ambient and operating condition are derived. The cooling efficiency and drain ratio are expressed using separation of variables, i.e. relative spray amount, ambient wet bulb depression and fogger configuration (droplet spectrum, geometry of fog rack etc.). The correlation for power increase obtained as function of net specific spray water flow can be applied to overspray mode of operation. It is confirmed that the power increase predicted matches field data within error less than 10% in the range of net specific water amount up to 0.4% overspray and ambient wet bulb depression from 3.35 to 13.8deg.
机译:得出了用于预测(1)排水质量流量,(2)进气温度下降和(3)功率增加到给定环境和运行条件的经验相关性。冷却效率和排水比使用变量的分离表示,即相对喷雾量,周围湿球下降和雾化器配置(液滴光谱,雾化架的几何形状等)。根据净喷射水流量获得的功率增加的相关性可以应用于过喷操作模式。可以确定的是,预测的功率增加与现场数据相匹配,在净比水高达0.3%到13.8deg的超喷量和周围湿球下降范围内,误差小于10%。