Kawasaki Heavy Industries launched the first model of L20A gas turbine, rated at 18MW, in 2001. After the first model was launched, continuing improvements in both performance and durability have been made. This paper describes the latest improvement activities, including cooling improvement of the 1st stage turbine blades using the results from an optical pyrometer thermal mapping system (Rotamap II) and performance improvements achieved by reducing the secondary air flow. In addition, by applying the non-cooled 2nd stage turbine blades made of single crystal material, plus improved rim sealing structure, cavity temperature was kept below the desired limit with a reduced amount of cooling air being required. KHI also developed a L20A "STEAM INJECTION" version. This system enables the utilization of the variable surplus steam of a cogeneration plant to increase the electric output . This paper describes the test result of L20A model gas turbine with steam injection capabilities. In the test, performance and emissions were measured as usual, but in addition, metal temperature of 1st stage blade was measured using the pyrometer system in order to confirm the propriety of the TIT de-rate schedule which keeps the metal temperature at the same level as the L20A "NORMAL" version under the steam injected condition.
机译:川崎重工在2001年推出了第一台额定功率为18MW的L20A燃气轮机。在推出第一款机型之后,性能和耐用性都得到了持续改善。本文介绍了最新的改进活动,包括使用光学高温计热成像系统(Rotamap II)的结果对第一级涡轮机叶片进行冷却改进,以及通过减少二次空气流实现的性能改进。另外,通过应用由单晶材料制成的非冷却的第二级涡轮机叶片,加上改进的轮辋密封结构,将腔体温度保持在期望的极限以下,并且需要减少的冷却空气量。 KHI还开发了L20A“蒸汽喷射”版本。该系统能够利用热电联产厂的可变剩余蒸汽来增加电力输出。本文介绍了具有蒸汽喷射能力的L20A型燃气轮机的测试结果。在测试中,照常测量性能和排放,但此外,使用高温计系统测量了第一级叶片的金属温度,以确认TIT降额计划的适当性,该计划将金属温度保持在同一水平作为在蒸汽注入条件下的L20A“ NORMAL”版本。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号