The fundamental design of high pressure joints such as crosses and tees has remained the same for many years. However, the introduction of commercially available high pressure equipment operating at 600 MPa and higher has demanded improved designs for these classic connections. This study presents a new design concept for reducing the stress concentration at intersecting crossbores. Both the finite element analysis and the fatigue test results from the standard high pressure design and the new design are compared. The new approach realizes a 17 - 25% reduction in the stress concentration factors and a 40% improvement in fatigue life test results when compared to the standard design.
机译:十字和三通等高压接头的基本设计多年来一直保持不变。但是,引入运行在600 MPa或更高压力下的商用高压设备,要求对这些经典连接进行改进的设计。这项研究提出了一种新的设计理念,以减少相交横孔处的应力集中。比较了标准高压设计和新设计的有限元分析和疲劳测试结果。与标准设计相比,新方法可将应力集中系数降低17-25%,并将疲劳寿命测试结果提高40%。