首页> 外文会议>Optics and Biophotonics in Low-Resource Settings IV >Comparison of low-cost handheld retinal camera and traditional table top retinal camera in the detection of retinal features indicating a risk of cardiovascular disease
【24h】

Comparison of low-cost handheld retinal camera and traditional table top retinal camera in the detection of retinal features indicating a risk of cardiovascular disease

机译:低成本手持式视网膜相机与传统台式视网膜相机在检测视网膜特征中的比较,表明存在心血管疾病的风险

获取原文
获取原文并翻译 | 示例

摘要

Retinal abnormalities associated with hypertensive retinopathy are useful in assessing the risk of cardiovascular disease, heart failure, and stroke. Assessing these risks as part of primary care can lead to a decrease in the incidence of cardiovascular disease-related deaths. Primary care is a resource limited setting where low cost retinal cameras may bring needed help without compromising care. We compared a low-cost handheld retinal camera to a traditional table top retinal camera on their optical characteristics and performance to detect hypertensive retinopathy. A retrospective dataset of N=40 subjects (28 with hypertensive retinopathy, 12 controls) was used from a clinical study conducted at a primary care clinic in Texas. Non-mydriatic retinal fundus images were acquired using a Pictor Plus hand held camera (Volk Optical Inc.) and a Canon CR1-Mark Ⅱ tabletop camera (Canon USA) during the same encounter. The images from each camera were graded by a licensed optometrist according to the universally accepted Keith-Wagener-Barker Hypertensive Retinopathy Classification System, three weeks apart to minimize memory bias. The sensitivity of the hand-held camera to detect any level of hypertensive retinopathy was 86% compared to the Canon. Insufficient photographer's skills produced 70% of the false negative cases. The other 30% were due to the handheld camera's insufficient spatial resolution to resolve the vascular changes such as minor A/V nicking and copper wiring, but these were associated with non-referable disease. Physician evaluation of the performance of the handheld camera indicates it is sufficient to provide high risk patients with adequate follow up and management.
机译:与高血压性视网膜病相关的视网膜异常可用于评估心血管疾病,心力衰竭和中风的风险。在初级保健中评估这些风险可以减少与心血管疾病相关的死亡。初级保健是一种资源有限的环境,在这种情况下,低成本的视网膜相机可在不影响保健的前提下提供所需的帮助。我们比较了低成本手持式视网膜相机和传统台式视网膜相机的光学特性和检测高血压性视网膜病变的性能。在德克萨斯州一家初级保健诊所进行的一项临床研究中,使用了N = 40名受试者(28名患有高血压性视网膜病,12名对照)的回顾性数据集。在同一次相遇期间,使用Pictor Plus手持相机(Volk Optical Inc.)和佳能CR1-MarkⅡ台式相机(Canon USA)采集了非散瞳视网膜眼底图像。根据普遍接受的Keith-Wagener-Barker高血压视网膜病变分类系统,由持照的验光师对每台摄像机的图像进行分级,每隔三周进行一次,以最大程度地减少记忆偏差。与佳能相比,手持相机检测任何水平的高血压性视网膜病变的灵敏度为86%。摄影师技能不足造成了70%的假阴性案件。其余30%是由于手持摄像机的空间分辨率不足以解决诸如轻微的A / V切口和铜线之类的血管变化,但这些疾病与疾病无关。医师对手持摄像机性能的评估表明,足以为高风险患者提供足够的随访和管理。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号