【24h】

Surface Water Source Heat Pump Air Conditioning System Simulation and Operation Performance Analysis

机译:地表水源热泵空调系统仿真与运行性能分析

获取原文
获取原文并翻译 | 示例

摘要

This paper established a heat pump system model containing heat pump unit model,AC load model and heat exchanger model utilizing the mass and energy balance and the structure's designing method.This paper also developed the surface water source heat pump air conditioning system simulation program by Visual Basic,and verified the simulation by the actual engineering project.In addition,this paper explored the impact of the surface water temperature and heat exchanger structure on the heat pump air conditioning system operation.The results shows that one degree drop of the surface water temperature leads t0 2.3 per cent increase of performance coefficient and a lOOm added length of the closed-loop surface water heat exchanger tube leads t0 0.08 per cent increase of performance coefficient.
机译:本文利用质量和能量平衡和结构的设计方法,建立了由热泵机组模型,交流负荷模型和换热器模型组成的热泵系统模型。基础,并通过实际工程项目进行了仿真验证。此外,本文还探讨了地表水温度和换热器结构对热泵空调系统运行的影响。结果表明,地表水温度下降了1度。导致t0性能系数增加2.3%,增加100m的闭环地表水热交换器管的长度导致t0性能系数增加0.08%。