In the criticality analysis of electric substations, the main difficulty is caused by the presence of reliability block diagrams (RBD) of non series-parallel kind (e.g. T-schemes). In these cases the Markov representation becomes very complicated since the redundancies consist of components of different kind. In this paper the criticality analysis of a railway substation was performed transforming a T-kind RBD into parallel-series schemes by means of cut-set procedures. After the transformation, the criticality of each subsystem was computed and then the opportunity for obtaining a uniform criticality for the various equally important subsystems were also investigated. The analytical-graphic method is based on the total probability theorem.
机译:在变电站的危险性分析中,主要困难是由于存在非串并联类型(例如T型)的可靠性框图(RBD)而引起的。在这些情况下,由于冗余由不同种类的组件组成,因此马尔可夫表示变得非常复杂。在本文中,对铁路变电站进行了临界分析,通过割集程序将T型RBD转换为并行系列方案。转换后,计算了每个子系统的临界度,然后还研究了为各个同样重要的子系统获得统一临界度的机会。分析图形方法基于总概率定理。