首页> 外文会议>The 5th Biomedical Engineering International Conference. >Development of the ultrasound power meter for therapeutic applications
【24h】

Development of the ultrasound power meter for therapeutic applications

机译:开发用于治疗用途的超声波功率计

获取原文
获取原文并翻译 | 示例

摘要

The total output power from a medical ultrasound transducer has to be measured due to various reasons but in general they are related to patient safety and assessment of performance. The objective of this work was to develop an ultrasound power meter to measure a total output power from therapeutic ultrasound devices. The implementation of this work utilizes a radiation force balance technique based on the method recommended in the International Electrotechnical Commission (IEC 61161). Ultrasound therapy unit and its transducer were used as an ultrasonic source. To verify the performance of the developed system, the ultrasonic power measurement results from our developed ultrasound power meter were compared with those from the commercial ultrasound power meter (UPM) at 5 nominal intensity values (0.5 W/cm2, 1 W/cm2, 1.5 W/cm2, 2 W/cm2, 3 W/cm2) with three frequencies, 0.86 MHz, 2 MHz and 3 MHz, and four different output pulse modes; continuous wave (100% duty cycle), 1∶2 (50% duty cycle), 1∶5 (20% duty cycle) and 1∶10 (10% duty cycle). The results show that the developed system is currently able to determine the ultrasonic output power in the frequency range from about 1 MHz to 3 MHz, and in the power range from 100 mW to approximately 15 W. Current efforts are being made to focus on testing the performance of the developed ultrasound power meter by comparing the results from the developed system with those from the standard system at the National Institute of Metrology, Thailand (NIMT) and developing a three axis positioning system with computer control for the alignment of the ultrasonic transducer.
机译:由于各种原因,必须测量医疗超声换能器的总输出功率,但总的来说,它们与患者安全和性能评估有关。这项工作的目的是开发一种超声波功率计,以测量治疗用超声波设备的总输出功率。这项工作的实施利用了基于国际电工委员会(IEC 61161)推荐方法的辐射力平衡技术。超声治疗仪及其换能器被用作超声源。为了验证所开发系统的性能,将我们开发的超声功率计的超声功率测量结果与商用超声功率计(UPM)在5个标称强度值(0.5 W / cm 2 ,1 W / cm 2 ,1.5 W / cm 2 ,2 W / cm 2 ,3 W / cm 2 < / sup>)具有三个频率,分别为0.86 MHz,2 MHz和3 MHz,以及四个不同的输出脉冲模式;连续波(100%占空比),1:2(50%占空比),1:5(20%占空比)和1:10(10%占空比)。结果表明,开发的系统当前能够确定大约1 MHz至3 MHz频率范围内以及100 mW至大约15 W功率范围内的超声输出功率。目前,人们正在努力集中精力进行测试通过将开发的系统的结果与泰国国家计量学会(NIMT)的标准系统的结果进行比较,并开发一种具有计算机控制的三轴定位系统来对超声换能器进行对准,从而开发出的超声功率计具有出色的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号