首页> 外文会议>4th International Symposium on Architectural Interchange in Asia; Sep 17-19, 2002; Chongqing, China >Field study on the effect by introducing a regional energy system at Kitakyushu Science and Research Park
【24h】

Field study on the effect by introducing a regional energy system at Kitakyushu Science and Research Park

机译:在北九州市科学研究园区引入区域能源系统进行实地研究

获取原文
获取原文并翻译 | 示例

摘要

In Kitakyushu Science and Research Park, a new district energy system has been introduced. In this study, we choose this system as a case study and carried an analysis on efficiency of the power generation and heat release utilization of fuel cell and gas engine in summer by using the recorded data. The results can be summarized as follows; 1) Although the power generation efficiencies of the gas engine and fuel cell are a little bit lower than standard designated value, they are almost running stably. 2) The collected heat energy is lower than the designated value. The heat release utilization, which is used for cooling and hot water, is fairly low. Considering the efficient use of energy, it is a key to have a good use of heat release when we introduce a district energy system. 3) The discard heat energy of the system is very big in this investigation in evaluating the whole systems. It is connected in the future of energy conservation to use primary energy efficiently.
机译:在北九州市科学研究园区,引入了新的区域能源系统。在这项研究中,我们选择该系统作为案例研究,并利用记录的数据对夏季燃料电池和燃气发动机的发电效率和放热利用进行了分析。结果总结如下: 1)尽管燃气发动机和燃料电池的发电效率略低于标准指定值,但它们几乎稳定运行。 2)收集的热能低于指定值。用于冷却和热水的放热利用率相当低。考虑到能源的有效利用,在引入区域能源系统时,充分利用热量释放是关键。 3)在评估整个系统的调查中,系统的废热能很大。节能的未来与之相连,可以有效地利用一次能源。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号