首页> 外文会议>4th European Conference on Underwater Acoustics Vol.2, Sep 21-25, 1998, Rome, Italy >EXPERIMENTAL VALIDATION OF A 3-D MODEL OF THE CLASSICAL LANGEVIN TRANSDUCER
【24h】

EXPERIMENTAL VALIDATION OF A 3-D MODEL OF THE CLASSICAL LANGEVIN TRANSDUCER

机译:经典朗格文传感器的3D模型的实验验证

获取原文
获取原文并翻译 | 示例

摘要

In this work, a 3-D matrix model of the classical Langevin transducer is evaluated and experimentally validated. A comparison between the frequency spectrum computed with this model and with a classical 1-D model is shown. It shows that the 3-D approach allows to predict the unwanted radial modes of the piezoceramic disk and of the masses, and also the coupling of these with the thickness-extensional modes. In order to experimentally validate the model, two sets of 13 pairs of loading masses, of increasing thickness, were manufactured. By sandwiching a piezoceramic disk between each pair of masses, we measured the experimental frequency spectrum, with and without pre-stressing the structure, and compared it with the computed results, finding a quite good agreement.
机译:在这项工作中,对经典Langevin换能器的3-D矩阵模型进行了评估和实验验证。显示了使用此模型和经典一维模型计算的频谱之间的比较。它表明3-D方法可以预测压电陶瓷盘和质量的不希望有的径向模式,也可以预测这些与厚度扩展模式的耦合。为了通过实验验证该模型,制造了两组13对厚度不断增加的加载质量。通过将压电陶瓷盘夹在每对质量之间,我们测量了有无预应力结构的实验频谱,并将其与计算结果进行了比较,从而找到了很好的一致性。