首页> 外文会议>49th Annual International Relay Conference Apr 23-25, 2001 Oak Brook, IL >The Effects of Ultrasonic Cleaning on Ultraminiature Electromechanical Relay Contacts
【24h】

The Effects of Ultrasonic Cleaning on Ultraminiature Electromechanical Relay Contacts

机译:超声波清洗对超小型机电继电器触点的影响

获取原文
获取原文并翻译 | 示例

摘要

The formation and implosion of microscopic bubbles during ultrasonic cleaning provides a scrubbing action that assists the cleaning process. Unfortunately, the ultrasonic cleaning process also subjects the components being cleaned to high frequency, high energy vibrations. In the case of ultraminiature electromechanical relays, ultrasonic cleaning of an assembly or circuit board containing relays subjects the relays, and therefore the relay contacts, armature, and other mechanical components, to ultrasonic vibrations. Excessive ultrasonic cleaning can cause premature contact wear or contact sticking, and damage to the armature or the coil. Relay contacts that have been subjected to excessive ultrasonic vibrations may develop deep grooves or other wear patterns that are inconsistent with typical relay operation. This may result in relay failures during the assembly process, or reduced reliability and inconsistent performance in the field. This paper presents a brief introduction to ultrasonic cleaning, and then demonstrates through a case study that severe damage can result from ultrasonic cleaning. Using ultrasonics to clean circuit board assemblies containing ultraminiature electromechanical relays is not a recommended practice.
机译:超声波清洁过程中微小气泡的形成和爆破提供了有助于清洁过程的擦洗作用。不幸的是,超声清洗过程也使被清洗的部件经受高频,高能量的振动。对于超小型机电继电器,对包含继电器的组件或电路板进行超声波清洗会使继电器(因此使继电器触点,电枢和其他机械组件)遭受超声波振动。过度的超声波清洁会导致触点过早磨损或触点粘连,并损坏电枢或线圈。受到过分超声波振动的继电器触点可能会形成深槽或其他磨损模式,这与典型的继电器操作不一致。这可能会导致继电器在组装过程中发生故障,或者可靠性降低,并且现场性能会出现不一致的情况。本文介绍了超声清洗的简要介绍,然后通过案例研究证明了超声清洗会导致严重损坏。建议不要使用超声波清洗包含超小型机电继电器的电路板组件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号