THE EFFECT OF THE PERIOSTEUM AND STRAIN GAGES ON THE STRUCTURAL RESPONSE OF HUMAN RIBS

机译:骨膜和应变计对人肋骨结构反应的影响

获取原文
获取原文并翻译 | 示例

摘要

The purpose of this study was to determine if the removal of the periosteum or the application of a strain gage has any significant effect on the structural response of human ribs. A total of 32 three-point bending tests were performed on 16 matched whole rib sections obtained from the left and right sides of five male human thoraces. For one test group, matched specimens were tested to determine the effect of removing the soft tissue and periosteum versus leaving it intact. For a second test group, matched specimens were tested to determine the effects of placing a strain gage on the tension side of the specimen versus no strain gage attachment. The specimens were tested using a servo-hydraulic material testing machine (MTS) at a displacement rate of 17.78 cm/s with a fixed testing span of 10.16 cm. Prior to testing, a microCT was used to obtain a detailed cross-sectional image of each specimen at the point of the impactor blade contact. There were no statistical differences in area moment of inertia (p=0.60), distance to the neutral axis (p=0.29), peak moment (p=0.14), peak impactor displacement (p=0.13), estimated peak stress (p=0.42), or estimated peak strain (p=0.15) between specimens with the periosteum and those without the periosteum. There were no statistical differences in area moment of inertia (p=0.76), distance to the neutral axis (p=0.20), peak moment (p=0.81), peak impactor displacement (p=0.91), estimated peak stress (p=0.59), or estimated peak strain (p=0.29) between specimens with a strain gage and those without a strain gage. In summary, neither the removal of the periosteum nor the application of a strain gage has any significant effect on the structural response of human ribs in dynamic three-point bending.
机译:这项研究的目的是确定骨膜的去除或应变计的应用是否对人肋骨的结构反应有任何重大影响。对从五个男性人类胸部的左侧和右侧获得的16个匹配的完整肋骨部分进行了总共32次三点弯曲测试。对于一个测试组,对匹配的标本进行测试,以确定去除软组织和骨膜与保持完整的效果。对于第二测试组,测试匹配的样本以确定相对于没有应变计附接的将应变计放置在样本的张紧侧上的效果。使用伺服液压材料测试机(MTS)以17.78 cm / s的位移速率和10.16 cm的固定测试跨度对样品进行测试。在测试之前,使用microCT在撞击叶片接触点获得每个样品的详细横截面图像。区域惯性矩(p = 0.60),到中性轴的距离(p = 0.29),峰值矩(p = 0.14),峰值冲击器位移(p = 0.13),估计峰值应力(p = 0.42),或带有骨膜的标本和没有骨膜的标本之间的估计峰值应变(p = 0.15)。区域惯性矩(p = 0.76),到中性轴的距离(p = 0.20),峰值矩(p = 0.81),峰值冲击器位移(p = 0.91),估计峰值应力(p = 0.59)或带有应变计的样本与没有应变计的样本之间的估计峰值应变(p = 0.29)。总之,在动态三点弯曲中,骨膜的去除或应变计的应用都不会对人肋骨的结构响应产生任何重大影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号