The method used for the selection of a Safety integrity Level (SIL) for a Safety Instrumented System (SIS) of a hazardous process should use a risk based approach to evaluate potential consequences and likelihoods,as well as the effectiveness of process safeguards.Process Safety Management,under OSHA 29 CFR Part 1910,requires an assurance of mechanical integrity for all emergency shutdown systems and safety critical controls.The International Society for Measurement and Control (ISA) promulgated an industry standard, S84.01 to assist in compliance with the PSM regulation in the United States,and the International Electrochemical Commission (IEC) created a similar standard for Europe.these standards specify that all electrical,electronic,and programmable electronic systems,used in SISs,are required to be designed such that they achieve a psecified SIL.These standards are performance based,giving guidance on how to select and achieve an appropriate SIL for a given SIS,but are not prescriptive to any particular methods or equipment.The SIL selectionh is critical since in many cases the SIS is the last layer of protection for the prevention of hazardous events.The probability of failure on demand of a SIS are quantitatively categorized into discrete integrity levels(i.e. SIL) by both industry standards.Since neither standard specifies requirements for integrity level selection,the determination of a SIL a SIS is based solely on reducing the risk of a process to a level acceptable or tolerable to each individual company.
机译:为危险过程的安全仪表系统(SIS)选择安全完整性等级(SIL)的方法应使用基于风险的方法来评估潜在的后果和可能性以及过程保障的有效性。根据OSHA 29 CFR Part 1910的要求,管理部门必须确保所有紧急停机系统和安全关键控制装置的机械完整性。国际测量与控制协会(ISA)颁布了行业标准S84.01,以帮助遵守PSM美国的相关法规以及国际电化学委员会(IEC)为欧洲创建了类似的标准。这些标准规定,要求对SIS中使用的所有电气,电子和可编程电子系统进行设计,以使其达到可分解的状态。 SIL。这些标准基于性能,为如何为给定的SIS选择和实现适当的SIL提供指导,但未规定对SIL的选择至关重要,因为在许多情况下SIS是防止危险事件的最后一层保护措施。按SIS的要求,发生故障的可能性可以定量地分为离散的完整性级别(即由于这两个行业标准都没有规定完整性等级选择的要求,因此确定SIL和SIS的SIL完全基于将过程风险降低到每个公司可以接受或容忍的水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号