In this work we propose a hybrid concurrent error detection (CED) scheme that combines the implication-based method with the parity check method. The parity check method is easy to implement and has high probability of detecting errors, while the implication-based method has high flexibility to be easily integrated with other CED methods for improidng the probability of detecting errors. In addition, fault diagnosis capability can even be enabled by integrating implications. We show that by combining these two methods, not only the probability of detecting errors can be significantly increased, but also the diagnosability of the target circuit can be effectively enhanced. A systematical flow is developed to add the required checking logic of implications into the most appropriate locations in the target circuit for detecting undetected errors by the parity check method. This minimizes the total number of the employed implications and thus the incurred area overhead. The experimental results show that 89.08% of area overhead is required yet the probability of detecting errors is improved from 88.32% to 97.73% by the proposed hybrid scheme. The results also show that the achievable diagnosability of our scheme enhances from 91.79% to 96.36% on average. More than 200 equivalent faults also become distinguishable in our scheme.
机译:在这项工作中,我们提出了一种混合并发错误检测(CED)方案,该方案将基于暗示的方法与奇偶校验方法相结合。奇偶校验方法易于实现并且具有较高的错误检测可能性,而基于蕴涵的方法具有很高的灵活性,可以轻松地与其他CED方法集成以实现错误检测的可能性。此外,甚至可以通过集成含义来启用故障诊断功能。我们表明,通过结合这两种方法,不仅可以显着增加检测错误的可能性,而且可以有效地增强目标电路的可诊断性。开发了系统的流程以将所需的含义检查逻辑添加到目标电路中最合适的位置,以通过奇偶校验方法检测未检测到的错误。这最小化了所采用的含义的总数,从而最小化了所产生的区域开销。实验结果表明,所提出的混合方案需要89.08%的区域开销,而将错误检测的概率从88.32%提高到97.73%。结果还表明,我们的方案可实现的可诊断性从91.79%平均提高到96.36%。在我们的方案中,也可以区分200多个等效故障。

著录项

  • 来源
  • 会议地点 Taipei(CN)
  • 作者

    Chih-Hao Wang; Tong-Yu Hsieh;

  • 作者单位

    Department of Electrical Engineering, National Sun Yat-sen University, Kaohsiung, Taiwan;

    Department of Electrical Engineering, National Sun Yat-sen University, Kaohsiung, Taiwan;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Observability;

    机译:可观察性;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号