摘要

The analysis performed in this paper starts from an EPANET model of the Tei-Colentina District water distribution system in Bucharest. The model was used in a previous study to assess the energy consumption of the pumping station. The present study is trying to assess the differences, with respect to energy consumption, between the previous demand driven EPANET model and a new pressure driven model, created with WaterNetGen (an EPANET extension) that allows taking into account leakages at pipe level. Although results show an increase of the energy consumption in the latter case, the pumping station still delivers the demand at a correct pressure level.
机译:本文进行的分析从布加勒斯特Tei-Colentina地区供水系统的EPANET模型开始。该模型在先前的研究中用于评估泵站的能耗。本研究试图评估以前的需求驱动的EPANET模型与使用WaterNetGen(EPANET扩展)创建的新压力驱动模型之间的能耗差异,该模型可以考虑管道级的泄漏。尽管结果表明在后一种情况下能耗增加,但泵站仍以正确的压力水平满足需求。