首页> 外文会议>2016 International Conference on System Reliability and Science >Influence investigation from the forced draught fan mode on the characteristics of an air-cooled power plant
【24h】

Influence investigation from the forced draught fan mode on the characteristics of an air-cooled power plant

机译:强制通风模式对风冷电厂特性的影响研究

获取原文
获取原文并翻译 | 示例

摘要

In view of the critical suction effect of the forced draught fans in the air-cooled steam condenser (ACSC), it is momentous to investigate and optimize the fan mode to acquire a better synthetical performance of the power plant. A verified numerical model of a 2×600MW power plant [1] is specified to discuss the influence from the different rotating speed regulation schemes on the performance of the air-cooled power plant at the design wind angle of β=22.5°. It is found that as a result of the rotating speed regulation of the forced draught fans, the improvement for the performance of the air-cooled power plant arise. It is concluded that the rotating speed regulation for the whole fan array should be proposed because the maximum net power elevation compared to the design case is applicable at all the appointed wind speeds for the fan array case.
机译:考虑到风冷式蒸汽冷凝器(ACSC)中的强制通风风扇的临界吸力效果,研究和优化风扇模式以获得电厂的更好综合性能非常重要。给出了一个2×600MW电厂的验证数值模型[1],以讨论在设计风向角为β= 22.5°时,不同的转速调节方案对风冷电厂性能的影响。已经发现,由于强制通风机的转速调节,导致了空气冷却发电厂的性能的提高。结论是,应该提出整个风扇阵列的转速调节方案,因为与设计方案相比,最大净功率提升适用于所有指定的风扇阵列风速。