摘要

The authors have been developing a new diagnostic method with pulse voltages instead of the DC and AC voltages in the conventional residual charge method. In this study, we applied pulse voltages with the pulse width of about 5 ms to removed XLPE cables at 22, 66 and 77 kV classes, and we succeeded to detect current signals related to water tree degradation. Then, we investigated the relationship between the residual charge signal and the AC breakdown strength of the removed cables. As a result, it was found that the ratio of the duration of the current signal related to water tree degradation to the rise time of the applied pulse voltage had strong correlation with the AC breakdown strength, and it can be a water tree degradation index.
机译:作者一直在开发一种新的诊断方法,该方法采用脉冲电压代替传统的残余充电方法中的直流和交流电压。在这项研究中,我们将脉冲宽度约为5 ms的脉冲电压应用于22、66和77 kV级的已拆除XLPE电缆,并且成功检测了与水树退化有关的电流信号。然后,我们研究了残留电荷信号与拆除的电缆的交流击穿强度之间的关系。结果,发现与水树退化有关的电流信号的持续时间与施加的脉冲电压的上升时间的比率与AC击穿强度具有很强的相关性,并且它可以是水树退化指标。