Digitized sampling adopts decentralized, independent sampling mode, which introduces a new problem of data synchronization to secondary system of substations, especially for relay protections. This paper analyzes the time delay of every sections in sampling and the causes of non-synchronized sampling data. It states two general applied data synchronization method in smart substations at present, one method is based on external synchronizing signal while the other is based on interpolation method for resampling. The paper also compares two important indexes of digital sampling, rated delay time and phase error. Then the paper presents two methods, steady-state indirect method and time-scale direct method, to measure sampling delay and in turn to solve the problems of data synchronization. The test data of practical project shows that both two methods are able to achieve microsecond precision, but time-scale direct method is more accurate and stable. At last, the paper gives some precautions and recommendations for application of digital sampling in smart substations.
机译:数字化采样采用分散,独立的采样方式,这给变电站的二次系统引入了数据同步的新问题,尤其是继电保护。本文分析了采样中每个部分的时间延迟以及采样数据不同步的原因。阐述了目前智能变电站中两种通用的数据同步方法,一种是基于外部同步信号,另一种是基于插值方法进行重采样。本文还比较了数字采样的两个重要指标:额定延迟时间和相位误差。然后提出了稳态间接法和时标直接法两种方法来测量采样延迟,进而解决数据同步问题。实际项目的测试数据表明,两种方法都可以达到微秒级的精度,但时标直接法更准确,更稳定。最后,本文提出了在智能变电站中应用数字采样的一些注意事项和建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号