In this paper, the fundamental advantages of series-connected voltage domains are briefly discussed in light of existing power distribution architectures for data centers. The key technical challenges of this architecture are addressed; and results from a working prototype system are presented as a proof of concept. In particular, a straightforward software-only solution is presented which eliminates the need for power conversion hardware between the distribution bus and server. Based on power-aware load balancing of web traffic and server frequency, this design is shown to provide adequate voltage regulation for a cluster of four web servers sharing the same line current. Compared with measurements of maximum server performance, the series-connected configuration shows only a minor reduction in net throughput. As a step toward improving system reliability and performance, a hardware supplement for over-voltage protection is presented along with measurements verifying its operation at full server load.
机译:在本文中,根据数据中心现有的配电架构,简要讨论了串联电压域的基本优势。解决了该架构的关键技术挑战;并给出了工作原型系​​统的结果作为概念证明。特别是,提出了一种简单的纯软件解决方案,该解决方案消除了对配电总线和服务器之间的电源转换硬件的需求。基于Web流量和服务器频率的功率感知负载平衡,该设计显示为四个共享相同线路电流的Web服务器群集提供了适当的电压调节。与最大服务器性能的测量结果相比,串联配置仅显示出净吞吐量的小幅下降。作为提高系统可靠性和性能的一步,我们提供了用于过压保护的硬件补充,以及用于验证其在满服务器负载下运行的测量结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号