首页> 外文会议>2012 IEEE EMBS Conference on Biomedical Engineering and Sciences. >Further validation of Normalized Symmetry Index and normalized cross-correlation in identifying gait asymmetry on restricted knee and ankle movement
【24h】

Further validation of Normalized Symmetry Index and normalized cross-correlation in identifying gait asymmetry on restricted knee and ankle movement

机译:标准化对称指数和标准化互相关的进一步验证可用于识别膝盖和踝关节活动受限的步态不对称

获取原文
获取原文并翻译 | 示例

摘要

This paper extends an initial investigation and application of gait asymmetry using wireless gyroscope, normalized Symmetry Index (SInorm), and normalized cross-correlation (Ccnorm). In this study, one side of the participant's lower exteremity movement is restricted using knee brace or ankle brace. Wireless gyroscopes are then attached to participant's left thigh, left shank, right thigh and right shank. Measurement data are collected for duration of one minute while participant is walking on a treadmill. The experimental results are satisfactory. Significant asymmetric gait was observed when the participant walks with knee brace or ankle brace on one side of the limbs. The knee brace produced greater asymmetry than ankle brace. These were apparent in both SInorm and Ccnorm.
机译:本文扩展了使用无线陀螺仪,归一化对称指数(SI norm )和归一化互相关(Cc norm )进行步态不对称的初步研究和应用。在这项研究中,使用膝盖支撑或脚踝支撑来限制参与者下肢运动的一侧。然后将无线陀螺仪连接到参与者的左大腿,左小腿,右大腿和右小腿。参与者在跑步机上行走时,在一分钟的持续时间内收集测量数据。实验结果令人满意。当参与者用四肢的一侧的膝盖支撑或脚踝支撑走路时,观察到明显的不对称步态。护膝比踝护具产生更大的不对称性。这些在SI norm 和Cc norm 中都显而易见。