This paper analyzes the way the different number of short-circuited turns during an inter-turn stator fault affects the functional behavior of a salient pole synchronous machine, while this is connected to an infinite bus. In order to achieve more accurate results, two subcases have been examined. In the first one, different number of turns belonging to the same phase is short-circuited, while in the second case the short-circuited turns belong to different phases; nevertheless, their respective number is almost the same. The geometry of the stator winding couldn't provide us with the possibility to simulate the exact same number of short-circuited turns resulting significant differences to both quantitative and qualitative magnitudes.
机译:本文分析了匝间定子故障期间短路匝数的不同对凸极同步电机(连接到无限母线)的功能行为的影响。为了获得更准确的结果,已经研究了两个子案例。在第一种情况下,短路属于同一相的匝数,而在第二种情况下,短路匝属于不同相。但是,它们各自的数量几乎相同。定子绕组的几何形状无法为我们提供模拟完全相同数量的短路匝的可能性,从而导致定量和定性幅度上的显着差异。