首页> 外文会议>2011 Fifth International Conference on Sensing Technology >Optimization of planar interdigitated electrode array for bioimpedance spectroscopy restriction of the number of electrodes
【24h】

Optimization of planar interdigitated electrode array for bioimpedance spectroscopy restriction of the number of electrodes

机译:平面交叉指形电极阵列的生物阻抗谱优化对电极数量的限制

获取原文
获取原文并翻译 | 示例

摘要

This paper concerns physical model of interdigitated sensor in the frequency range 102−107 Hz. A theoretical approach is proposed to optimize the use of the sensor for bioimpedance spectroscopy. CoventorWare® software was used to modelize in three dimensions the interdigital sensor system for measuring electrical impedance of biological medium. Complete system simulation by Finite element method (FEM) was used for sensor sensitivity optimization. The influence of geometrical parameters (number of fingers, width of the electrodes), on the impedance spectroscopy of biological medium was studied.
机译:本文涉及频率为10 2 −10 7 Hz的叉指式传感器的物理模型。提出了一种理论方法来优化传感器在生物阻抗光谱中的使用。使用CoventorWare ®软件在三个维度上对用于测量生物介质电阻抗的叉指式传感器系统进行建模。通过有限元方法(FEM)进行的完整系统仿真被用于传感器灵敏度的优化。研究了几何参数(手指的数量,电极的宽度)对生物介质阻抗谱的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号