The test method of oxygen permeability of plastic pipes which applied for cold and hot water in buildings was described in this paper. A few problems in oxygen permeability test have been found,discussed and solved. Some influencing factors, such as test temperature and test pressure, have been studied. The oxygen permeability of three different pipes (PE-RT pipe, PE-x pipe, PB pipe) were evaluated and discussed respectively, and some advices were brought forward on these pipes using in practice.
机译:本文介绍了用于建筑物冷热水的塑料管的透氧性的测试方法。已经发现,讨论和解决了透氧性测试中的一些问题。研究了一些影响因素,例如测试温度和测试压力。分别对三种不同的管道(PE-RT管道,PE-x管道,PB管道)的透氧性进行了评估和讨论,并在实践中对这些管道提出了一些建议。