PHASIC VARIATIONS AN D MAGNITUDE OF PRESSURE RECOVERY DISTAL TO HUMAN CORONARY ARTERY STENOSES DURING AN GIOPLASTY

机译:假体成形术期间人冠状动脉狭窄的压力恢复远距变化

获取原文
获取原文并翻译 | 示例

摘要

Distal pressure recovery coefficients (c_(pr) = kc_(pr∞)) were determined from pulsatile hemodynamic computations for the 32 patient group of Wilson et al. 1988 during coronary angioplasty in conjunction with quantitative angiography and measurements of coronary flow reserve (CFR). Before angioplasty, values of the factor k(t)ranged 34 times high than a reference value, c_(pr∞)=0.18, and varied during the flow acceleration and deceleration phases of the cardiac cycle. After angioplasty, values of k(t) ranged from 0.8-1.4, roughly the same magnitude as c_(pr∞) =0.46, and also varied phasically.
机译:远端压力恢复系数(c_(pr)= kc_(pr∞))是根据Wilson等人的32个患者组的脉动血流动力学计算确定的。 1988年,在冠状动脉成形术中结合定量血管造影和冠状动脉血流储备(CFR)的测量。在血管成形术之前,系数k(t)的值范围是参考值c_(pr∞)= 0.18的34倍,并且在心动周期的血流加速和减速阶段发生变化。血管成形术后,k(t)的值在0.8-1.4范围内,与c_(pr∞)= 0.46大致相同,并且也有阶段性变化。