'Wedge effect' in stenosed coronary artery assessed using a PressureWire: change in pressure waveform during percutaneous coronary intervention in a patient with a coronary artery-left ventricular fistula.

机译:使用PressureWire评估狭窄的冠状动脉中的“楔效应”:在冠状动脉左心室瘘患者中,经皮冠状动脉介入治疗期间压力波形的变化。

获取原文
获取原文并翻译 | 示例
           

摘要

In this case report, we describe the recovery of abnormal coronary pressure waveform using a PressureWire Certus during percutaneous coronary intervention in a patient with severe stenosis in the proximal segment of the left anterior descending coronary artery. Since the diastolic pressure in the distal left anterior descending coronary artery was lower than that in the aorta, the pressure waveform before percutaneous coronary intervention represented the left ventricular pressure through a fistula due to a "wedge effect" in the stenosis as if the pulmonary artery wedge pressure determined by a Swan-Ganz catheter reflected the pressure in the distal portion (left atrium). We diagnosed this case coronary artery-left ventricular fistula based on the above findings. PressureWire Certus may be a valuable tool with which to estimate the hemodynamics in a patient with a coronary anomaly.
机译:在此病例报告中,我们描述了在左冠状动脉前降支近端严重狭窄的患者中,经皮冠状动脉介入治疗期间使用PressureWire certus冠状动脉压力波形的异常恢复。由于远端左前降支冠状动脉的舒张压低于主动脉,因此经皮冠状动脉介入治疗前的压力波形代表了由于狭窄的“楔效应”导致的通过瘘管的左心室压力,就像肺动脉一样由Swan-Ganz导管确定的楔形压力反映了远端部分(左心房)的压力。根据上述发现,我们诊断出该病例为冠状动脉左心室瘘。 PressureWire Certus可能是有价值的工具,可用来评估冠状动脉异常患者的血流动力学。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号